Custom development is standard.

Users who sought custom solutions and partnered with SYKO to meet their in-house requirements have not been disappointed. SYKO is regarded as a premier provider of innovative system solutions.

SYKO General
30 or more customer-specific modifications per year
Extreme requirements are met.
Shock, vibration
Temperature
Fluctuations in supply
Disturbances, lightning strikes, load shedding in inductive networks
Grid interruptions
Grid dips during cold start
Innovative, patented topologies
Step-up/step-down converters with or without galvanic isolation
Regenerator topology (US Pat. No. 5,991,166, D. Pat. No. 195 15 210)
Input values
24/36/48/60/96/110 V batteries
13.5 – 154 V without switching + transients up to 300 V
12/24/42 V batteries
4 – 38/6 – 38/9 – 85 V + transients up to 110 V
18V DC – 264 V AC (universal input)
400 V – 1200 V DC
600V – 1600 V DC
680 V – 5000 V DC/AC + transients up to 16 kV/2 ms
Initial values
Up to 15 output voltages
No-load proof, short-circuit proof, overload-proof, cross-load independent
2 – 640 V with input voltage ranges up to 1:10
With or without galvanic isolation
System extensions
Active transient protection (SYKO Patent Nos. 0402367 + 3804074) for inrush current limiting and overvoltage absorption (transient suppression).
Active hold-up time of 10 ms to 1 s for DC and AC inputs, and constant mains failure hold-up time down to minimum input voltage (U_in min) across the entire input voltage range.
Extension of active storage time into the seconds range using capacitor storage, or into the hours range using batteries or rechargeable batteries.
Auxiliary outputs: transient-free and EMC-clean, referenced to the input voltage.
Switchable outputs / Inhibit function
Combination of low-voltage and high-voltage outputs with very wide input voltage ranges
Output regulation with a dropout voltage of approx. 100 mV per 5 A of output current.
Regulated outputs with total device power for heating or cooling, featuring polarity reversal.
Setpoint specification via reference voltage or reference current
Actual value feedback via reference voltage or reference current
Reverse polarity protection: passive (diode) or active (power loss reduction)
Increase in power and input voltage through cascading of regenerator stages (US Pat. No. 6,094,366; German Pat. No. 195 05 417)
Single-stage PFC for AC input voltages up to 2100 V at 16 2/3 to 60 Hz (sine and square wave)
Minimal modification times: 6–10 weeks from receipt of order to pre-series delivery.

While the market typically cites development costs of €50,000, SYKO demonstrates its flexibility and commitment to customer satisfaction with an average cost of €10,000. This is clearly evidenced by multiple development projects that are consistently completed in parallel.

Now SYKO is not viewed by its customers as a supplier to a niche market, but as a partner to solve their in-house needs. If you check the market, there are more suppliers supplying this market and we say that the number of suppliers and not the size of the manufacturing facility sets the standard. In terms of price, you would like to have standard goods, but the specifications can only be fulfilled to a limited extent. Now you have to learn to make functionality calculable in addition to performance.